Table 13. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Memory DIMM n
Status Scrub failure
detected. (n = DIMM
number)
Error A memory scrub
failure has been
detected.
1. (Trained technician only) Remove
the affected microprocessor and
check the microprocessor socket
pins for any damaged pins. If a
damage is found, replace the system
board (see “Removing the system
board” on page 354 and “Replacing
the system board” on page 359).
2. (Trained technician only) Swap the
affected microprocessor, if there are
more than one microprocessor
installed. If the problem follows the
microprocessor, replace the affected
microprocessor (see “Removing a
microprocessor and heat sink” on
page 347 and “Replacing a memory
module” on page 313).
3. (Trained technician only) Replace
the system board (see “Removing
the system board” on page 354 and
“Replacing the system board” on
page 359).
806f040c-2001xxxx
806f040c-2002xxxx
806f040c-2003xxxx
806f040c-2004xxxx
806f040c-2005xxxx
806f040c-2006xxxx
806f040c-2007xxxx
806f040c-2008xxxx
806f040c-2009xxxx
806f040c-200axxxx
806f040c-200bxxxx
806f040c-200cxxxx
Memory DIMM
disabled for DIMM n
Status. (n = DIMM
number)
Info DIMM disabled.
1. Make sure the DIMM is installed
correctly (see “Replacing a memory
module” on page 313).
2. If the DIMM was disabled because
of a memory fault (memory
uncorrectable error or memory
logging limit reached), follow the
suggested actions for that error
event and restart the server.
3. Check the IBM support website for
an applicable retain tip or firmware
update that applies to this memory
event. If no memory fault is
recorded in the logs and no DIMM
connector error LED is lit, you can
re-enable the DIMM through the
Setup utility or the Advanced
Settings Utility (ASU).
158 System x3530 M4 Type 7160: Installation and Service Guide

Table of Contents

Other manuals for IBM System x3530 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3530 M4 and is the answer not in the manual?

IBM System x3530 M4 Specifications

General IconGeneral
BrandIBM
ModelSystem x3530 M4
CategoryServer
LanguageEnglish

Related product manuals