Table 13. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
8007020f-2582xxxx Sensor No PCI I/O
has transitioned to
critical from a less
severe state.
Error A sensor has
transitioned to
critical from less
severe.
1. This is a UEFI detected event. The
UEFI diagnostic code for this event
can be found in the logged IMM
message text. Please refer to the
UEFI diagnostic code in the "UEFI
diagnostic code" section of the Info
Center for the appropriate user
response.
80070614-2201xxxx Sensor TPM Phy
Pres Set has
transitioned to
non-recoverable.
Error A sensor has
transitioned to
non-recoverable.
1. This is a UEFI detected event. The
UEFI diagnostic code for this event
can be found in the logged IMM
message text. Please refer to the
UEFI diagnostic code in the "UEFI
diagnostic code" section of the Info
Center for the appropriate user
response.
806f011b-0701xxxx The Front USB
connector has
encountered a
configuration error.
Error The system had
detected an
internal connection
error.
Reseat the front USB cable on the
system board.
806f011b-0701xxxx The Front Video
connector has
encountered a
configuration error.
Error The system had
detected an
internal connection
error.
Reseat the front video cable on the
system board.
806f0123-2101xxxx Reboot of system
[ComputerSystemElementName]
initiated by
[WatchdogElementName].
Info This message is for
the use case when
an implementation
has detected a
Reboot by a
Watchdog
occurred.
No action; information only.
806f0125-0c01xxxx Front panel entity
has been detected
Absent.
Info A front panel
entity has been
detected absent.
No action; information only.
806f0013-1701xxxx A front panel NMI
has occurred on
system %1. (%1 =
CIM_ComputerSystem.
ElementName)
Error An operator
information panel
NMI/diagnostic
interrupt has
occurred.
1. Check the device driver.
2. Reinstall the device driver.
3. Update all device drivers to the
latest level.
4. Update the firmware (UEFI and
IMM) (see “Updating the firmware”
on page 71).
806f0313-1701xxxx A software NMI has
occurred on system
%1. (%1 =
CIM_ComputerSystem.
ElementName)
Error A software NMI
has occurred.
1. Check the device driver.
2. Reinstall the device driver.
3. Update all device drivers to the
latest level.
4. Update the firmware (UEFI and
IMM) (see “Updating the firmware”
on page 71).
170 System x3530 M4 Type 7160: Installation and Service Guide