Table 13. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
4000000c-00000000 OS Watchdog
response [arg1] by
[arg2].
Info This message is for
the use case where
an OS Watchdog
has been enabled
or disabled by a
user.
No action; information only.
4000000d-00000000 DHCP[%1] failure,
no IP address
assigned.(%1 = IP
address,
xxx.xxx.xxx.xxx)
Info A DHCP server
has failed to assign
an IP address to
the IMM.
Complete the following steps until the
problem is solved:
1. Make sure that the Chassis
Management Module network cable
is connected.
2. Make sure that there is a DHCP
server on the network that can
assign an IP address to the IMM.
4000000e-00000000 Remote Login
Successful. Login ID:
[arg1] from [arg2] at
IP address [arg3].
Info The specified user
has logged in to
the Integrated
Management
Module.
No action; information only.
4000000f-00000000 Attempting to %1
server %2 by user
%3.(%1 = Power Up,
Power Down, Power
Cycle, or Reset; %2 =
IBM_ComputerSystem.ElementName;
%3 = user ID)
Info A user has used
the IMM to
perform a power
function on the
server.
No action; information only.
40000010-00000000 Security: Userid: '%1'
had %2 login failures
from WEB client at
IP address %3.(%1 =
user ID; %2 =
MaximumSuccessiveLoginFailures
(currently set to 5 in
the firmware); %3 =
IP address,
xxx.xxx.xxx.xxx)
Error A user has
exceeded the
maximum number
of unsuccessful
login attempts
from a web
browser and has
been prevented
from logging in for
the lockout period.
Complete the following steps until the
problem is solved:
1. Make sure that the correct login ID
and password are being used.
2. Have the system administrator reset
the login ID or password.
40000011-00000000 Security: Login ID:
'%1' had %2 login
failures from CLI at
%3.(%1 = user ID;
%2 =
MaximumSuccessiveLoginFailures
(currently set to 5 in
the firmware); %3 =
IP address,
xxx.xxx.xxx.xxx)
Error A user has
exceeded the
maximum number
of unsuccessful
login attempts
from the
command-line
interface and has
been prevented
from logging in for
the lockout period.
Complete the following steps until the
problem is solved:
1. Make sure that the correct login ID
and password are being used.
2. Have the system administrator reset
the login ID or password.
178 System x3530 M4 Type 7160: Installation and Service Guide