80010b01-2d01ffff Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has
asserted. (PCH Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Non-recoverable
sensor going high has asserted.
May also be shown as 80010b012d01ffff or 0x80010b012d01ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server),
that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
2. Check the ambient temperature. You must be operating within the specifications (see Server Features and
specifications for more information).
3. Make sure that the heat sink for microprocessor n.
4. (Trained technician only) Replace system board.
80030006-2101ffff Sensor [SensorElementName] has deasserted. (Sig Verify Fail)
Explanation: This message is for the use case when an implementation has detected a Sensor has deasserted.
May also be shown as 800300062101ffff or 0x800300062101ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0509
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
80030012-2301ffff Sensor [SensorElementName] has deasserted. (OS RealTime Mod)
Explanation: This message is for the use case when an implementation has detected a Sensor has deasserted.
May also be shown as 800300122301ffff or 0x800300122301ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0509
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
80010b01-2d01ffff • 80030012-2301ffff
388
System x3100 M5 Type 5457: Installation and Service Guide