7. Install the bezel (see “Replacing the bezel” on page 188).
8. Reconnect the external cables and power cords; then, turn on the attached
devices and turn on the server.
Removing the hot-swap power supply
This procedure applies only to the 5U server model with hot-swap power supplies.
When you remove or install a hot-swap power supply, observe the following
precautions.
Statement 5
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current from
the device, ensure that all power cords are disconnected from the power source.
1
2
Statement 8
CAUTION:
Never remove the cover on a power supply or any part that has the following
label attached.
Hazardous voltage, current, and energy levels are present inside any component
that has this label attached. There are no serviceable parts inside these
components. If you suspect a problem with one of these parts, contact a service
technician.
Attention: During normal operation, each power-supply bay must contain either
a hot-swap power supply or a hot-swap power-supply filler for proper cooling.
To remove a hot-swap power supply on the 5U server model with hot-swap power
supplies, complete the following steps.
Chapter 6. Removing and replacing components 263