202-902-000 MemStr Test Failed
Explanation: Memory size is insufficient to run the test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Ensure that all memory is enabled by checking the "Available System Memory" in the "Resource Utilization"
section of the DSA Diagnostic Event log.
2. If necessary, access the Configuration/Setup Utility program by pressing F1 during system boot and enable all
memory.
3. Make sure that the DSA Diagnostic code is at the latest level.
4. Run the test again.
5. Execute the standard DSA memory diagnostics to validate all memory.
6. If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for
the next corrective action.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
DSA Nvidia GPU test results
The following messages can result when you run the Nvidia GPU test.
409-000-000 NVIDIA User Diagnostic Test Passed
Explanation: NVIDIA User Diagnostic test passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
202-902-000 409-000-000
Appendix C. DSA diagnostic test results 625

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3100 M5 Type 5457 and is the answer not in the manual?

IBM x3100 M5 Type 5457 Specifications

General IconGeneral
BrandIBM
Modelx3100 M5 Type 5457
CategoryServer
LanguageEnglish

Related product manuals