EasyManua.ls Logo

IBM x3100 M5 Type 5457 - Page 442

IBM x3100 M5 Type 5457
688 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
806f0323-2101ffff Power cycle of system [ComputerSystemElementName] initiated by watchdog
[WatchdogElementName]. (IPMI Watchdog)
Explanation: This message is for the use case when an implementation has detected a Power Cycle by Watchdog
occurred.
May also be shown as 806f03232101ffff or 0x806f03232101ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0374
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f040c-2001ffff [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 1)
Explanation: This message is for the use case when an implementation has detected that Memory has been
Disabled.
May also be shown as 806f040c2001ffff or 0x806f040c2001ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
1. Make sure the DIMM is installed correctly.
2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit
reached), follow the suggested actions for that error event and restart the server.
3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory
event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the
DIMM through the Setup utility or the Advanced Settings Utility (ASU).
806f0323-2101ffff 806f040c-2001ffff
426
System x3100 M5 Type 5457: Installation and Service Guide

Table of Contents

Related product manuals