806f0823-2101ffff Watchdog Timer interrupt occurred for [WatchdogElementName]. (IPMI Watchdog)
Explanation: This message is for the use case when an implementation has detected a Watchdog Timer interrupt
occurred.
May also be shown as 806f08232101ffff or 0x806f08232101ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0376
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f090c-2001ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 1)
Explanation: This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c2001ffff or 0x806f090c2001ffff
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response:
1. Reseat the DIMM, and then restart the server.
2. Replace DIMM n. (n = DIMM number)
806f090c-2002ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 2)
Explanation: This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c2002ffff or 0x806f090c2002ffff
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response:
1. Reseat the DIMM, and then restart the server.
2. Replace DIMM n. (n = DIMM number)