W.305000A [W.305000A] An invalid date and time have been detected.
Explanation: RTC Date and Time Incorrect
Severity: Warning
User response: Complete the following steps:
1. Check IMM/chassis event log. This event should immediately precede 0068002 error. Service that event or any
other battery related errors.
2. Use F1 Setup to reset date and time. If problem returns after a system reset, replace CMOS battery.
3. If problem persists then check IBM Support website for an applicable service bulletin or firmware update that
applies to this error.
4. (Trained service technician only) Replace the system board.
W.3058009 [W.3058009] DRIVER HEALTH PROTOCOL: Missing Configuraiton. Requires Change Settings From
F1.
Explanation: DRIVER HEALTH PROTOCOL: Missing Configuration. Requires Change Settings From F1
Severity: Warning
User response: Complete the following steps:
1. Go to System Settings > Settings > Driver Health Status List and find a driver/controller reporting Configuration
Required status.
2. Search for the driver menu from System Settings and change settings appropriately.
3. Save settings and restart system.
W.305800A [W.305800A] DRIVER HEALTH PROTOCOL: Reports 'Failed' Status Controller.
Explanation: DRIVER HEALTH PROTOCOL: Reports 'Failed' Status Controller
Severity: Warning
User response: Complete the following steps:
1. Reboot the system.
2. If problem persists, switch to backup UEFI or reflash current UEFI image.
3. (Trained service technician only) Replace system board.
W.305800B [W.305800B] DRIVER HEALTH PROTOCOL: Reports 'Reboot' Required Controller.
Explanation: DRIVER HEALTH PROTOCOL: Reports 'Reboot' Required Controller
Severity: Warning
User response: Complete the following steps:
1. No action required – system will reboot at the end of POST.
2. If problem persists, switch to backup UEFI or reflash current UEFI image.
3. (Trained service technician only) Replace system board.
W.305000A • W.305800B