218-904-000 Brocade:ExternalEthLoopbackTest Failed
Explanation: A failure was detected during the Loopback test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check or replace SFP/cable.
2. Rerun the test.
3. Verify whether the firmware is at proper level.
4. Rerun the test.
5. If the problem remains, contact your IBM technical-support representative.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
218-905-000 Brocade:SerdesEthLoopbackTest Failed
Explanation: A failure was detected during the Loopback test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Rerun the test.
2. Verify whether the firmware is at proper level.
3. Rerun the test.
4. If the problem remains, contact your IBM technical-support representative.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
218-904-000 218-905-000
Appendix C. DSA diagnostic test results 531

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3100 M5 Type 5457 and is the answer not in the manual?

IBM x3100 M5 Type 5457 Specifications

General IconGeneral
MemoryUp to 32 GB
Form FactorTower
ChipsetIntel C222
ProcessorIntel Xeon E3-1200 v3 series, Intel Core i3 series, Intel Pentium series
Memory TypeDDR3 ECC
Memory Slots4 DIMM slots
RAID SupportRAID 0, 1, 10
NetworkDual Gigabit Ethernet
Storage Bays4 x 3.5-inch
Operating System SupportRed Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware
Expansion Slots1 PCIe 3.0 x8