217-800-000 HDD Test Aborted
Explanation: HDD Test Aborted. The test was canceled.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify that Hard drive supports self test and self test logging.
4. If the problem remains, contact your technical-support representative.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
217-900-000 HDD Test Failed
Explanation: HDD Test Failed. The hard drive self-test detected a failure.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify the firmware is at the latest level.
4. Rerun the test.
5. If the problem remains, contact your technical-support representative.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
217-800-000 217-900-000
542
System x3100 M5 Type 5457: Installation and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3100 M5 Type 5457 and is the answer not in the manual?

IBM x3100 M5 Type 5457 Specifications

General IconGeneral
BrandIBM
Modelx3100 M5 Type 5457
CategoryServer
LanguageEnglish

Related product manuals