11-3
11
CONTROL COMMAND
Controlling the radio with CI-V (Continued)
D Command table
Cmd. Sub cmd. Data
Description
00 Send frequency data.
(for transceive operation)
01 00 Select LSB mode
(for transceive operation)
01 Select USB mode
(for transceive operation)
02 Select AM mode
(for transceive operation)
03 Select CW mode
(for transceive operation)
04 Select RTTY mode
(for transceive operation)
07 Select CW-R mode
(for transceive operation)
08 Select RTTY-R mode
(for transceive operation)
02 Read band edge frequencies
03 Read operating frequency
04 Read operating mode
05 Set operating frequency
06 00 Select LSB mode
01 Select USB mode
02 Select AM mode
03 Select CW mode
04 Select RTTY mode
07 Select CW-R mode
08 Select RTTY-R mode
07 Select VFO mode
00 Select VFO A
01 Select VFO B
A0 Equalize VFO A and VFO B
B0 Exchange VFO A and VFO B
08 Select memory mode
0001−
0201*
Select memory channel
*P1=0200, P2=0201
09 Memory write
0A Memory to VFO
0B Memory clear
0E 00 Scan stop
01 Programmed/memory scan start
02 Programmed scan start
22 Memory scan start
D0 Set scan resume OFF
D3 Set scan resume ON
0F 00 Turn the split function OFF
01 Turn the split function ON
10 00 Select 10 Hz (or 1 Hz) tuning steps
01 Select 100 Hz tuning steps
02 Select 1 kHz tuning step
03 Select 5 kHz tuning steps
04 Select 9 kHz tuning steps
05 Select 10 kHz tuning steps
11 0 Send/read attenuator OFF.
20 Send/read attenuator ON (20 dB).
13 00 Announce with voice synthesizer
01 ( 00=all data 01=frequency and
S-meter; 02=receive mode)
02
Cmd. Sub cmd. Data
Description
14 01 0 to 255 Send/read [AF] level setting
(0=max. CCW to 255=max. CW)
02 0 to 255 Send/read [RF] level setting
(0=max. CCW to 255=11 o'clock)
03 0 to 255 Send/read [SQL] level setting
(0=11 o'clock to 255=max. CW)
06 0 to 255 Send/read NR level setting
(0=0% to 255=100%)
07 0 to 255 Send/read Inside [PBT] setting (0= max.
CCW, 128=center, 255=max. CW)
08 0 to 255 Send/read Outside [PBT] setting
( 0= max. CCW, 128=center,
255=max. CW)
09 0 to 255
Send/read CW Tone Pitch setting
(0=300 Hz to 255=900 Hz (5 Hz steps))
0A 0 to 255 Send/read RF power setting
(0=minimum to 255=100%)
0B 0 to 255 Send/read MIC gain setting
(0=0% to 255=100%)
0C 0 to 255 Send/read Key speed level setting
(0=6 wpm to 255=60 wpm)
0D 0 to 255 Send/read [MNF] setting (0=max. CCW,
128=center, 255=max. CW)
0E 0 to 255 Send/read COMP level setting
(0=0 to 255=10)
0F 0 to 255 Send/read Break-IN delay setting
(0=2.0 d to 255=13.0 dots)
12 0 to 255 Send/read NB level setting
(0=0% to 255=100%)
16 0 to 255 Send/read VOX gain setting
(0=0% to 255=100%)
17 0 to 255 Send/read Anti VOX gain setting
(0=0% to 255=100%)
15 01 Read squelch status
02 Read S-meter level
11 Read RF power meter
12 Read SWR meter
13 Read ALC meter
16 02 0 Send/read Preamp OFF
1 Send/read Preamp ON
12 0 Send/read AGC OFF
1 Send/read AGC Fast
2 Send/read AGC Slow
22 0 Send/read Noise Blanker OFF
1 Send/read Noise Blanker ON
40 0 Send/read Noise Reduction OFF
1 Send/read Noise Reduction ON
41 0 Send/read Auto Notch function OFF
1 Send/read Auto Notch function ON
44 0 Send/read Speech compressor OFF
1 Send/read Speech compressor ON
46 0 Send/read VOX function OFF
1 Send/read VOX function ON
47 0 Send/read Break-IN function OFF
1 Send/read Semi Break-IN function ON
2 Send/read Full Break-IN function ON
48 0 Send/read Manual Notch function OFF
1 Send/read Manual Notch function ON
4F 0 Send/read Twin Peak Filter OFF
1 Send/read Twin Peak Filter ON
50 0 Send/read Dial lock function OFF
1 Send/read Dial lock function ON
19 00 Read the transceiver ID
1A 00
See p. 11-6
Send/read memory contents
01
See p. 11-5
Send/read band stacking register con-
tents
Previous view