EasyManuals Logo

IFR 2026 User Manual

IFR 2026
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #120 background imageLoading...
Page #120 background image
REMOTE OPERATION
5-12 46882/439
Carrier frequency (source-specific)
CFRQ
Set Carrier Frequency (short form)
:VALUE
Set Carrier Frequency
:INC
Set Carrier Frequency step
Data type :
Decimal Numeric Program Data
Allowed suffices :
Any one of: GHZ, MHZ, KHZ or HZ
Default suffix :
HZ
:UP
Go UP one step
:DN
Go DOWN one step
:RETN
Return to original setting
:XFER
Transfer current value to be the new setting
Data type :
None
Allowed suffices :
None
Default suffix :
None
:PHASE
Adjust Phase Offset of Carrier in degrees
Data type :
Decimal Numeric Program Data
Allowed suffices :
DEG
Default suffix :
DEG
Examples:
CFRQ:VALUE 2.54MHZ;INC 10KHZ
CFRQ:UP;XFER
CFRQ?
Prepares message containing information on Carrier Frequency setting in the
following format:
:CFRQ:VALUE <nr2>; INC <nr2>
Example:
:CFRQ:VALUE 1000000000.0;INC 25000.0