88
HDK-99 1803 VER1 (E)
5.2 Settings from the Menu
MENU (2/4)
Menu Item
Initial
setting
Setting value Description, Remarks
MENU DATA
ALL VF
VIDEO OUTPUT MODE
SDI OUT
CAM CAM, HD Q-TV It switches the signal output from the SDI OUT connector.
MONITOR OUT
MONI MONI, SYNC
It switches the signal output from the MONITOR OUT
connector.
MONI SDI OUT
VF
MONI, VF, RETURN, HD
Q-TV,
It switches the signal output from the MONI SDI OUT
connector.
Sets the gain values allocated to the M and H positions of the
GAIN SELECT switch on the right side of the camera.
MID/HIGH GAIN MODE
MID GAIN
-3dB -6 to +12dB
Sets the medium gain value allocated to the M position of the
GAIN SELECT switch.
HIGH GAIN
+6dB -3 to +18dB
Sets the high gain value allocated to the H position of the
GAIN SELECT switch.
FILTER SERVO MODE
SERVO CONT
SERVO SERVO, MANUAL
SERVO : Sets to automatic control.
MANUAL : Sets to manual control.
BATTERY WARNING
BATT WARN VOLT
11.0V 10.5 to 13.5V Sets the battery voltage threshold to display warning.
BARS MODE
BARS MODE
MULTI
FULL, MULTI
FULL : Displays the BARS signal conventionally used.
MULTI : Displays the multiformat BARS signal.
BARS ON
OFF ON, OFF Turns the color bar signal ON/OFF.
FAN CONTROL
FAN CONT MODE
AUTO
AUTO, SLOW, FAST,
QUIET, STOP
AUTO : Automatically changes the cooling fan speed
according to the internal temperature level.
SLOW : Sets the fan to SSLOW for 5 minutes. After 5
minutes, the mode changes to AUTO.
FAST : It increases the fan speed.
QUIET : Stops the fan until the external temperature
becomes about 35
. Above that temperature the
fan is operated automatically.
STOP : Keeps the fan stopped as long as the internal
temperature does not reach a critical level. If the
power is turned on again, it returns to AUTO.
* If the QUIET, STOP modes are chosen, the surface
temperature of the box may become higher than normal.
TIMER
--- (information display)
It displays the period for the FAN to restart when FAN
CONT MODE is set to SLOW or STOP.
HEAD TOP
---
(information display)
SSLOW : Fan speed is very slow.
SLOW : Fan speed is slow.
NOR : Fan speed is normal.
FAST : Fan speed is fast.
HEAD SIDE
---
ADAPTOR
---
VF CONT
---
FAN CONDITION
HEAD TOP
---
(information display)
OK : Normal
NG : Fan is stopped.
HEAD SIDE
---
ADAPTOR
---
H PHASE CONTROL
Adjusts the horizontal phase when using external sync.
H PHASE
0.0 -100 to +100
Sets so that the phase of the internal SYNC signal matches
the phase of the external SYNC signal. The internal SYNC
advances in the direction of -100 in relation to the external
synch, and delays in the direction of +100.
Can only be set during self-operation.
TIME SETTING
TIME
--- HH : MM : SS
Sets the time and date when saving the file to the memory
card.
DATE(YY/MM/DD)
--- YY / MM / DD

Table of Contents