SD1 Series Inverters Function Parameters
-69-
Function
code
Name Description Default Modify
P07.01
Parameter
copy
0: No operation
1:
Upload the local function parameter to the
keypad
2:
Download the keypad function parameter to
local address (including the motor parameters)
3:
Download the keypad function parameter to
local address (excluding the motor parameter of
P02 and P12 group)
4:
Download the keypad function parameters to
local address (only for the motor parameter of
P02 and P12 group)
Note: After finish 1~4, the parameter will restore
to 0 and the uploading and downloading does
not include P29.
0
P07.02
Key function
selection
0x00~0x27
Ones place: QUICK/JOG key function
0: Null
1: Jogging
2: Switch display state via shift key
3: Switch between FWD/REV rotation
4: Clear UP/DOWN setting
5: Coast to stop
6: Switch running command ref. mode in order
7: Quick commission mode (based on
non-default parameter)
Tens place:
0: keys unlocked
1: Lock all keys
2: Lock part of the keys (lock PRG/ESC key
only)
0x01
P07.03
QUICK/JOG
the shifting
sequence of
running
command
When P07.02
=6, set the shifting sequence of
running command channels.
0: Keypad control→terminals control
→communication control
1: Keypad control←→terminals control
2: Keypad control←→communication control
3: Terminals control←→communication control
0