Version 2.5 (11/2020) UL
Translation of the original operating manual
Start-up and operation
Under voltage error
Supply voltage too low:
Ignore: Error is not displayed.
Warning: Error is indicated by fault LED ashing ve times.
The conveying process is not interrupted.
Immediate stop: Error is indicated by fault LED ashing ve times.
The conveying process is interrupted.
Motor error
Monitoring of the motors:
Ignore: Error is not displayed.
Warning: Error is indicated by fault LED ashing three times.
The LED goes out when the error is no longer present. Further motors connected to the
MultiControl rotate.
Immediate stop: Error is indicated by fault LED ashing three times.
Further motors connected to the MultiControl stop.
General control error
Monitoring of the control system:
Ignore: Error is not displayed.
"Immediate stop" and "Normal stop" have the same function.
The control error 1–8 settings have no function.
Press the "Submit" button to transfer the modied parameters to the MultiControl.
Changes only come into eect when the control is switched o/on.