EasyManuals Logo

Interroll MultiControl AI User Manual

Interroll MultiControl AI
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #58 background imageLoading...
Page #58 background image
58 of 140
Version 2.5 (11/2020) UL
Translation of the original operating manual
Assistance in the event of faults
Power Ready Net run Fault Meaning Priority
- - - Flashes x6 Voltage error, overvoltage 4
- - - Flashes x7 Temperature in the MultiControl too high. 6
- - - Flashes x8 Overload protection for the brake resistor
active.
7
- - - Flashes x9 Handshake communication interrupted.
See instructions on ZPA and ZPA+
applications.
- - - Flashes x10 No connection to the neighbouring
devices. See instructions on ZPA and ZPA+
applications.
- - - Flashes x11 A congured neighbouring device has an
error (see ZPA+, "RemoteEmergency" in
the error log)
If several errors occur at the same time, only the error with the highest priority is displayed.
¾ To eliminate the errors, refer to „Troubleshooting“ on page 59.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interroll MultiControl AI and is the answer not in the manual?

Interroll MultiControl AI Specifications

General IconGeneral
BrandInterroll
ModelMultiControl AI
CategoryControl Systems
LanguageEnglish