Version 2.5 (11/2020) UL
Translation of the original operating manual
Assistance in the event of faults
Power Ready Net run Fault Meaning Priority
- - - Flashes x6 Voltage error, overvoltage 4
- - - Flashes x7 Temperature in the MultiControl too high. 6
- - - Flashes x8 Overload protection for the brake resistor
active.
7
- - - Flashes x9 Handshake communication interrupted.
See instructions on ZPA and ZPA+
applications.
- - - Flashes x10 No connection to the neighbouring
devices. See instructions on ZPA and ZPA+
applications.
- - - Flashes x11 A congured neighbouring device has an
error (see ZPA+, "RemoteEmergency" in
the error log)
If several errors occur at the same time, only the error with the highest priority is displayed.
¾ To eliminate the errors, refer to „Troubleshooting“ on page 59.