6700SR Refrigerated Sampler
33
Example 6 Storm Water Runoff Sampling (continued)
41
RESET RAIN HISTORY?
YES
NO
Select YES.
42
“LEVEL” CONDITION:
SET POINT
RANGE
Select SET POINT.
43
“LEVEL” SET POINT
0
.
25
ft
(0.001-30.000)
Enter 0.25.
44
ENABLED WHEN:
ABOVE SET POINT
BELOW SET POINT
Select ABOVE SET POINT.
45
ONCE ENABLED,
STAY ENABLED?
YES
NO
Select YES.
46
SAMPLE AT ENABLE?
YES
NO
Select YES.
47
PAUSE RESUME
1. HH:MM DD HH:MM DD
2. HH:MM DD HH:MM DD
CLEAR
DONE
Select DONE.
Screen will say “End of Part A” then “Beginning of Part B.”
48
UNIFORM TIME PACED
FLOW PACED
EVENT PACED
NONUNIFORM TIME
Select FLOW PACED.
49
PACED BY:
FLOW PULSES
FLOW MODULE VOLUME
Select FLOW MODULE VOLUME.
50
FLOW BETWEEN
SAMPLE EVENTS:
2500
gal
(0.001-99999)
Enter 2500.
51
SAMPLE AT START?
YES
NO
Select NO.
52
1
BOTTLES PER
SAMPLE EVENT (1- 18)
Enter 1.
53
SWITCH BOTTLES ON:
NUMBER OF SAMPLES
TIME
Select NUMBER OF SAMPLES.

Table of Contents