OPERATING AND MAINTENANCE HANDBOOK
Antishearing operations
An electronic control unit stops the lowering for 5-6 seconds, when
the distance between the arm and frame ends is 60 mm approx. (anti-
shearing safety).
When the lowering is locked, it is necessary:
•bring the joystick in standstill position,
•wait for 5-6 seconds checking that the persons being side the platform
do not risk to be trapped or crushed between scissors,
•give again the lowering command.
Baery connection plug
This safety device disconnects the power and control circuits of bat-
teries and the baery charger solely remains connected.
Make sure the baeries are disconnected before carrying out the
electric equipment maintenance.
IT10122 - IT12122
The baery connection plug is placed in the le box.