OPERATING AND MAINTENANCE HANDBOOK
Before the charge
Before starting the baery charge it is necessary to check the elec-
trolyte level and, if necessary, ll up till all elements are completely
covered.
•Open the boxes.
•Open the electrolyte lling caps.
•Check the level and if necessary ll up with distilled water.
•Close the caps and wipe away the liquid that might have come out.
The sulphuric acid contained in the solution could cause serious in-
juries; if it is unintentionally poured , wash immediately the objects
or the surfaces with abundant water.
If the acid comes into contact with the skin, wash immediately with
abundant water and consult a doctor.
It is recommended to always wear gloves and protective glasses du-
ring the maintenance operations of baeries.
Charge start
The recharge is to be carried out in a suitable room, well ventilated
and separate from the working room, because baeries generates
inammable gases, which can cause explosions if they come into
contact with ames or sparks.
The recharge is to be carried out with open boxes.
By connecting a mains cable to the le back outlet (2), the baery
charger is automatically started aer a few seconds.