OPERATING AND MAINTENANCE HANDBOOK
Before the charge
Before starting the baery charge it is necessary to check the elec-
trolyte level and, if necessary, ll up till all elements are completely
covered.
•Open the boxes.
•Open the electrolyte lling caps.
•Check the level and if necessary ll up with distilled water.
•Close the caps and wipe away the liquid that might have come out.
The sulphuric acid contained in the solution could cause serious in-
juries; if it is unintentionally poured , wash immediately the objects
or the surfaces with abundant water.
If the acid comes into contact with the skin, wash immediately with
abundant water and consult a doctor.
It is recommended to always wear gloves and protective glasses du-
ring the maintenance operations of baeries.
Charge start
The recharge is to be carried out in a suitable room, well ventilated
and separate from the working room, because baeries generates
inammable gases, which can cause explosions if they come into
contact with ames or sparks.
The recharge is to be carried out with open boxes.
By connecting a mains cable to the le back outlet (2), the baery
charger is automatically started aer a few seconds.
2
IT10122 - IT12122