OPERATING AND MAINTENANCE HANDBOOK
• Check that inclination warning light blinks under SQ1 operating
height
•Li platform and check that above SQ1 operating height:
- inclination warning light is on.
- the alarm sounds.
- all movements, lowering excluded, are stopped.
• Lower platform under SQ1 operating height and check that all move-
ments have been restored.
Lower platform completely, drive machine forward and remove
wedges.
Carry out tests in all four directions: forward – backward – right-
ward – leward.
•Lower platform completely.
• Place an obstacle of 30 mm under one of the protections against
overturning to avoid its lowering.
• Position a wedge B measuring about:
under each le, front and rear wheel for right transversal inclina-
tion; drive machine on it; li platform and carry out following
tests.
- repeat the above mentioned test positioning the wedges under each
right front and rear wheel.
During the second test, the machine must be put in the same position
with respect to the ground, while altering the wedge position (See
drawing on the side).
IT10122 - IT12122
Protections against overturning
- 38 mm
During normal machine operation, the protections against overturning
automatically lower when platform is lied and they are completely
lowered when the platform reaches the SQ1 operating height; on the
contrary, traction and steering are blocked.