Gb Fr
324501D revision07 - 49 -
De
V1 V3 V2
JP1
ONOFF
JP2
JP3
JP4
Microswitch JP4 position "On/R3" relay function
"On" relay
"R3" relay
JP1
ONOFF
JP2
JP3
JP4
V1 V3 V2
JP1
ONOFF
JP2
JP3
JP4
2.3.5- Particularity of
ORRDORRD
ORRDORRD
ORRD receiver on DIN rail
The ORRD receiver mounted on DIN rail
has an «On/R3» relay whose function is
selected using the programming
microswitch «
JP4
».
This relay can take the «On» relay
function (activated by the «On/Off» button
on certain transmitters) or the control relay
No. 3 function «R3».
«Power supply» connection
«On/R3» relay connection
«R1» relay connection
«R2» relay connection
«JP4» Microswitch
Position of
JP4
and function of «On/R3» relay :
- When microswitch
JP4
is set to the «OFF» position, the «On/R3» relay is
considered as an «On» relay and will only be actuated by pressing the «On/Off»
button on a transmitter equipped with this type of button.
- When microswitch
JP4
is set to the «ON» position, the «On/R3» relay becomes
the third function relay «R3» with operation and programming similar to that of
relays R1 and R2.
Note :
The program settings for relay R3 are saved in the event that microswitch
JP4
is
set to the «OFF» position.