INSTRUCTION MANUAL
Alarm name
(Japanese)
Alarm name
(English)
Class Description
AIS 㺏㺵㺎㺯 032 AIS(Alarm 032) Alarm For AIS function=On, an error from the AIS receiver is received
(ALR)
AIS 㺏㺵㺎㺯 035 AIS(Alarm 035) Alarm For AIS function=On, an error from the AIS receiver is received
(ALR)
Table 4.5-5 Notification list
Alarm name
(Japanese)
Alarm name
(English)
Class Description
ࢪࣕ࢖ࣟタᐃ Set Gyro Status Requires setting of true bearing.
ࡲࡶ࡞ࡃ TM ࣜࢭࢵࢺ TM Reset Status For TM, the own ship position is out of 60% of the radius of PPI.
ᶵෆ ᗘୖ󰩝 High Temperature Caution Adjusting the LCD brilliance due to internal temperature control.
GPS  ఩⢭ᗘప GPS(HDOP) Caution Received excessive HDOP value beyond the setting.
Table 4.5-6 Radar alarm list
Alarm name
(Japanese)
Alarm name
(English)
Class Description
㺸㺎㺞㺼㺎㺏㺵㺎 1㐍ධ Area1(Approach) Alarm Echo in area 1.
㺸㺎㺞㺼㺎㺏㺵㺎 2㐍ධ Area2(Approach) Alarm Echo in area 2.
㺸㺎㺞㺼㺎㺏㺵㺎 1㞳⬺ Area1(Secession) Alarm No echo in area 1
㺸㺎㺞㺼㺎㺏㺵㺎 2㞳⬺ Area2(Secession) Alarm No echo in area 2
㺸㺎㺞㺼㺎㺏㺵㺎 1㡿ᇦእ Area1(Out of Range) Alarm y Rectangle area 1 is out of range
y Creation of area 1 is out of range
㺸㺎㺞㺼㺎㺏㺵㺎 2㡿ᇦእ Area2(Out of Range) Alarm y Rectangle area 1 is out of range
y Creation of area 2 is out of range
TT ༴㝤┠ᶆ TT(CPA/TCPA) Alarm TT is changed to a dangerous ship
TT ᪂つ┠ᶆ TT(New Target) Alarm TT is automatically acquired
TT ┠ᶆࣟࢫ TT(Lost) Alarm TT is lost
TT 㡿ᇦ TT(Out of Range) Alarm TT is too far to be tracked
TT ᭱኱ᤕᤊ TT(Max Target) Status Manually acquired when the number of acquisition reached
maximum
TT ᭱኱ᤕᤊ TT(Max Target) Status Detected when DSP tries to acquire 11 targets or more
DSP notifies the maximum target alarm occurrence of automatic
acquisition to the TT process task, then the TT process task notifies
it to the alarm task
EBL1/VRM1 㡿ᇦ EBL/VRM1(Out) Status The floating position of EBL1/VRM1 in the latitude/longitude
floating setting is out of the radius of PPI
EBL2/VRM2 㡿ᇦ EBL/VRM2(Out) Status The floating position of EBL2/VRM2 in the latitude/longitude
floating setting is out of the radius of PPI

Table of Contents

Other manuals for JRC JMA-3300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JRC JMA-3300 Series and is the answer not in the manual?

JRC JMA-3300 Series Specifications

General IconGeneral
BrandJRC
ModelJMA-3300 Series
CategoryRadar
LanguageEnglish

Related product manuals