5. Insert the Phillips 4x6-mm at-head mounng screws into the two aligned holes and ghten the
screws. Ensure that the two holes in the rear of the side mounng-rails are aligned with the
remaining two holes in the side panel. See Figure 59 on page 118.
Figure 59: Aaching the Side Mounng-Rail to the Switch Chassis
6. Insert the Phillips 4x6-mm at-head mounng screws into the remaining two holes in the side
mounng-rails and ghten the screws.
7. Have one person grasp both sides of the switch, li the switch, and posion it in the rack, aligning
the side mounng-rail holes with the threaded holes in the front post of the rack. Align the boom
hole in both the front-mounng brackets with a hole in each rack rail, making sure that the chassis
is level. See Figure 60 on page 118.
Figure 60: Mounng the Switch to the Front Posts of a Rack
8. Have a second person secure the front of the switch to the rack by using the appropriate screws for
your rack.