Table 37: Parts Required for Connecng an EX Series Switch to Earth Ground
(Connued)
Switch Earthing
Terminal
Locaon
Grounding
Cable
Requirements
Grounding Lug
Specicaons
Screws and
Washers
Addional
Informaon
EX2300 Rear panel of
the chassis
EX2300
switches
except
EX2300-24
MP and
EX2300-48
MP models
—14 AWG
(2 mm²),
minimum
90°C wire,
or as
permied by
the local
code
EX2300-24
MP and
EX2300-48
MP models
—14-10
AWG STR
(2.5-6 mm²),
12-10 AWG
SOL (4-6
mm²)
minimum
90°C wire,
or as
permied by
the local
code—not
provided
EX2300
switches except
EX2300-24MP
and
EX2300-48MP
models—Panduit
LCC10-14AW-L
or equivalent—
not provided
EX2300-24MP
and
EX2300-48MP
models—Panduit
LCA10-10L or
equivalent—not
provided
EX2300
switches
except
EX2300-24
MP and
EX2300-48
MP models
Two
10-32
x .25 in.
screws
with #10
split-lock
washer—
not
provided
Two #10
at
washers
—not
provided
EX2300-24
MP and
EX2300-48
MP models
One Pan
Phillips
M 4 x 6
mm
Nickel
plated
screw—
provided