Table 37: Parts Required for Connecng an EX Series Switch to Earth Ground
(Connued)
Switch Earthing
Terminal
Locaon
Grounding
Cable
Requirements
Grounding Lug
Specicaons
Screws and
Washers
Addional
Informaon
EX3200,
EX3300,
and
EX3400
Rear panel of
the chassis
14 AWG
(2 mm²),
minimum 90° C
wire, or as
permied by
the local code
Panduit
LCC10-14BWL or
equivalent—
not provided
Two
10-32 x .25 i
n. screws
with #10
split-lock
washer—
not provided
Two #10 at
washers—
not provided
For EX3200
Switches, see
"Special Instrucons
to Follow Before
Connecng Earth
Ground to an EX
Series Switch" on
page 139.
EX4200,
EX4500,
and
EX4550
Le side of
the chassis
14 AWG
(2 mm²),
minimum 90° C
wire, or as
permied by
the local code
Panduit
LCC10-14BWL or
equivalent—
not provided
Two 10-32
x .25 in.
screws with
#10 split-
lock washer
not provided
Two #10 at
washers—
not provided
See "Special
Instrucons to
Follow Before
Connecng Earth
Ground to an EX
Series Switch" on
page 139.
EX6210 Rear panel of
the chassis
(on lower le
side)
The grounding
cable must be
the same gauge
as the power
feed cables and
as permied by
the local code.
Panduit LCD2-14A-
Q or equivalent
—provided
Two ¼ -20
x 0.5 in.
screws with
#¼” split-
washer
—provided
Two #¼” at
washers—
provided