Special Instrucons to Follow Before Connecng Earth Ground to an EX Series Switch
Table 38 on page 139 lists the special instrucons that you might need to follow before connecng
earth ground to a switch.
Table 38: Special Instrucons to Follow Before Connecng Earth Ground to an EX Series Switch
Switch Special Instrucons
EX2300-C You must install the EX2300-C in a restricted-access locaon and ensure that the chassis is
always properly grounded. The EX2300-C has a two-hole protecve grounding terminal
provided on the chassis. We recommend that you use this protecve grounding terminal as
the preferred method for grounding the chassis regardless of the power supply
conguraon. However, if addional grounding methods are available, you can also use
those methods. For example, you can use the grounding wire in the AC power cord or use
the grounding terminal or lug on a DC power supply. This tested system meets or exceeds
all applicable EMC regulatory requirements with the two-hole protecve grounding
terminal.
EX3200 and
EX4200
Some early variants of EX3200 and EX4200 switches for which the Juniper Networks
model number on the label next to the protecve earthing terminal is from 750-021
xxx
through 750-030
xxx
require 10-24x.25 in. screws.