Table 62: show chassis temperature-thresholds Output Fields
Field Name Field Descripon
Item Chassis component. You can congure for the threshold informaon for components such as the chassis,
the Roung Engines, and FPC for each slot in each FRU to display in the output. By default, informaon is
displayed only for the chassis and the Roung Engines.
Fan speed Temperature thresholds, in degrees Celsius, for the fans to operate at normal and at high speed.
NormalThe temperature threshold at which the fans operate at normal speed and when all the fans
are present and funconing normally.
HighThe temperature threshold at which the fans operate at high speed or when a fan has failed or is
missing.
NOTE: An alarm is not triggered unl the temperature exceeds the threshold sengs for a yellow or amber
alarm or a red alarm.
Yellow or amber alarm Temperature threshold, in degrees Celsius, that trigger a yellow or amber alarm.
NormalThe temperature threshold that must be exceeded on the component to trigger a yellow or
amber alarm when the fans are running at full speed.
Bad fanThe temperature threshold that must be exceeded on the component to trigger a yellow or
amber alarm when one or more fans have failed or are missing.
Red alarm Temperature threshold, in degrees Celsius, that trigger a red alarm.
NormalThe temperature threshold that must be exceeded on the component to trigger a red alarm
when the fans are running at full speed.
Bad fanThe temperature threshold that must be exceeded on the component to trigger a red alarm
when one or more fans have failed or are missing.
Fire Shutdown Temperature threshold, in degrees Celsius, for the switch to shut down.
When a temperature alarm is triggered, you can idenfy the condion that triggered it by running the
show chassis environment command to display the chassis temperature values for each component and
comparing those with the temperature threshold values, which you can display by running the show
chassis temperature-thresholds command.
For example, for FPC 3:
250

Table of Contents

Other manuals for Juniper EX2300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX2300 Series and is the answer not in the manual?

Juniper EX2300 Series Specifications

General IconGeneral
SoftwareJunos OS
ModelEX2300
Ports24 or 48 10/100/1000BASE-T ports
Uplinks4 x 1GbE/10GbE SFP+/SFP uplinks
Power SupplyInternal or external power supply options
Rack Units1U
PoE/PoE+ PortsAvailable on some models (EX2300-C and EX2300)
Operating Temperature0° to 45°C
Input Voltage100 to 240 VAC
Layer 3 FeaturesRIP, OSPF, VRRP
Layer 2 FeaturesVLAN, STP, RSTP, MSTP, LACP
Security Features802.1X, DHCP snooping
ManagementCLI, Web UI, SNMP

Related product manuals