• Keep ber-opc cable connecons clean. Microdeposits of oil and dust in the canal of the transceiver
or cable connector can cause loss of light, reducon in signal power, and possibly intermient
problems with the opcal connecon.
• To clean the transceiver canal, use an appropriate ber-cleaning device such as RIFOCS Fiber
Opc Adaptor Cleaning Wands (part number 946). Follow the instrucons in the cleaning kit you
use.
• Aer cleaning the transceiver, make sure that the connector p of the ber-opc cable is clean.
Use only an approved alcohol-free ber-opc cable cleaning kit such as the Opptex Cletop-
S
®
Fiber Cleaner. Follow the instrucons in the cleaning kit you use.
Power O a QFX5240 Switch
Before you remove the power cord to power o a QFX5240 switch:
• Ensure that you have taken the necessary precauons to prevent electrostac discharge (ESD)
damage. See No Link Title.
• Ensure that you do not need to forward trac through the switch.
Ensure that you have the following parts and tools available to power o the switch:
• An ESD grounding strap
• An external management device such as a PC
• An RJ-45-to-DB-9 rollover cable to connect the external management device to the console port
To power o a QFX5240 switch:
1. Connect to the switch using one of the following methods:
• Connect a management device to the console (CON) port on a QFX5240 switch. For instrucons
about connecng a management device to the console (CON) port, see Connect a Device to a
Management Console Using an RJ-45 Connector.
• Shut down the QFX5240 from a management device on your out-of-band management network.
For instrucons about connecng a management device to the management (MGMT) port, see
Connect a Device to a Network for Out-of-Band Management.
2. Shut down Junos OS from the external management device.
For QFX5240 systems: