For mulmode transmission, modal dispersion, rather than chromac dispersion or aenuaon, usually
limits the maximum bit rate and link length. For single-mode transmission, modal dispersion is not a
factor. However, at higher bit rates and over longer distances, chromac dispersion limits the maximum
link length.
An ecient opcal data link must have enough light to exceed the minimum power that the receiver
requires to operate within its specicaons. In addion, the total dispersion must be within the limits
specied for the type of link in the Telcordia Technologies document GR-253-CORE (Secon 4.3) and
Internaonal Telecommunicaons Union (ITU) document G.957.
When chromac dispersion is at the maximum allowed, its eect can be considered as a power penalty
in the power budget. The opcal power budget must allow for the sum of component aenuaon,
power penales (including those from dispersion), and a safety margin for unexpected losses.
Calculang Power Budget and Power Margin for Fiber-Opc Cables
IN THIS SECTION
How to Calculate Power Budget for Fiber-Opc Cables | 51
How to Calculate Power Margin for Fiber-Opc Cables | 52
Use the informaon in this topic and the specicaons for your opcal interface to calculate the power
budget and power margin for ber-opc cables.
TIP: You can use the Hardware Compability Tool to nd informaon about the pluggable
transceivers supported on your Juniper Networks device.
To calculate the power budget and power margin, perform the following tasks:
How to Calculate Power Budget for Fiber-Opc Cables
To ensure that ber-opc connecons have sucient power for correct operaon, you need to calculate
the link's power budget, which is the maximum amount of power it can transmit. When you calculate
the power budget, you use a worst-case analysis to provide a margin of error, even though all the parts
of an actual system do not operate at the worst-case levels. To calculate the worst-case esmate of
power budget (P
B
), you assume minimum transmier power (P
T
) and minimum receiver sensivity (P
R
):
51