QFX5240 Environmental Requirements and Specicaons
You must install the switch in a rack and house it in a dry, clean, well-venlated, and temperature-
controlled environment.
Follow these environmental guidelines:
The site must be as dust-free as possible, because dust can clog air intake vents and lters, reducing
the eciency of the switch cooling system.
Maintain ambient airow for normal switch operaon. If the airow is blocked or restricted, or if the
intake air is too warm, the switch might overheat. As a result, the switch temperature monitor might
shut down the device to protect the hardware components.
Table 13: QFX5240 Switch Environmental Tolerances
Descripon Tolerance
Altude With DAC Cables: At 32° F through 104° F (0° C through 40° C), there
is no performance degradaon up to 6000 feet (1828.8 meters)
With Opcs: At 32° F through 104° F (0° C through 40° C), Sea level
Relave humidity, operang Normal operaon ensured in relave humidity range of 5% through
90%, non-condensing
Temperature
Normal operaon ensured in the temperature range of 32° F
through 104° F (0° C through 40° C)
Nonoperang storage temperature in shipping container: –40° F
through 158° F (–40° C through 70° C)
Seismic Designed to comply with Zone 4 earthquake requirements in
accordance with NEBS GR-63-CORE, Issue 3.