EasyManua.ls Logo

Juniper QFX5240 - QFX5240 Cooling System; QFX5240 Cooling System Description

Juniper QFX5240
140 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 10: QFX5240 AC PSM LED Color and State
(Connued)
LED Color PSM State
12V Fault (OVP, UVP, OCP, SCP and OTP)
Fan stopped working for 15 seconds and standby mode.
QFX5240 Cooling System
IN THIS SECTION
QFX5240 Cooling System Descripon | 32
QFX5240 Cooling System Descripon
IN THIS SECTION
Fan Modules | 33
Airow | 35
Power Supply Cooling System | 36
The cooling system components work together to keep all switch components within the acceptable
temperature range.
When the switch operates normally, the fans operate at lower than full speed. If a fan fails or the
ambient temperature rises above a threshold, the switch's cooling system automacally adjusts the
speed of the remaining fans to keep the temperature within the acceptable range. If the maximum
temperature specicaon is exceeded and the system cannot be adequately cooled, the switch shuts
down some or all of the hardware components.