Table 27: Chassis Alarm Messages for QFX5240
(Connued)
Component Alarm Type CLI Message Recommended Acon
Temperature
sensors
Major (red)
FPC 0 Temperature Hot
Check environmental condions
and alarms on other devices. Ensure
that environmental factors (such as
hot air blowing around the
equipment) do not aect the
temperature sensor. If the condion
persists, the device might shut
down.
Minor (yellow)
FPC 0 Temperature Warm
Check environmental condions
and alarms on other devices. Ensure
that environmental factors (such as
hot air blowing around the
equipment) do not aect the
temperature sensor.
FPC 0 Temp Sensor Fail
Check the system log for the
following error message and report
the message to customer support:
Roung Engine Major (red)
RE
RE number
/var partition is full
File storage is at capacity. Reduce
unnecessary les to free space.
Minor (yellow)
RE
RE number
/var partition is high
File storage is reaching capacity.
Reduce unnecessary les to free
space.
Management
Ethernet
interface
Major (red)
Management interface
management-
interface-name
down on
node
Check whether a cable is connected
to the management Ethernet
interface, or whether the cable is
defecve. Replace the cable, if
required.
116