EasyManuals Logo

K-TRON K-Vision User Manual

K-TRON K-Vision
121 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #75 background imageLoading...
Page #75 background image
Docu-No.: 0590020601-EN Rev. 1.6.0 Page 75
Alarm Messages- Cause and Remedy 4
System alarms 4.1
46 DRIVE CMD
HIGH
The drive command has exceed the
value <DRV CMD HI> Limit in the
<ALARM> menu.
Check for proper feeding of
material.
Check for bridging in hopper
Check for adequate product in
hopper
Lower the operating setpoint <SP>.
Increase the <DRV CMD HI> value
in the <ALARM> menu.
Check for motor rotation.
Replace KCM if drive has failed.
Check motor.
Check speed sensor.
47 DRIVE CMD
LOW
The drive command has dropped
below the value <DRV CMD LO>
Limit in the <ALARM> menu.
Raise the operating setpoint <SP>.
Increase the <DRV CMD LO>
value in the <ALARM> menu.
48
CHECK_MOTOR_B
RUSHES
DC motor brushes may be wearing
out and ready to fail.
Motor brushes need inspection and
replacement if worn.
If brushes are OK, re-enter a
relevant brush life number in the
Performance sub-menu.
49
Reset while running
It is set if the feeder was running
before the power down or reset
occurred.
Check power supply
50 Actiflow Failure Actiflow has an alarm. Check Status
62 Battery Low The KCM back-up batteries have
failed.
Check there is the "shipping
insulator" still installed in the
battery circuit.
The battery jumper JP-8 is
removed.
Replace battery.
Alarm Num- Alarm
Cause Remedy
Table page 7 of 7

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the K-TRON K-Vision and is the answer not in the manual?

K-TRON K-Vision Specifications

General IconGeneral
BrandK-TRON
ModelK-Vision
CategoryControl Panel
LanguageEnglish

Related product manuals