Material Antifreeze (Wabcothyl)
Cleaning cloths
Precondition The machine is shut down.
The machine is fully vented, the pressure gauge reads 0 psig.
Machine cooled down.
All compressed air consumers are disconnected and the air outlet valves are open.
Danger of fire or explosion caused by the spontaneous ignition of antifreeze.
Never top up antifreeze unless the machine is stopped and cooled down.
Danger of injury from compressed air!
The frost protector is under pressure when operating; serious injury can result from loosen‐
ing or opening components under pressure.
Decompress the frost protector
Fig. 41 Filling the frost protector
1 Shut-off valve
A Open
B Closed
2 Bowl clamp ring
3 Frost protector bowl
1. Open the shut-off valve ( A ) and wait about 30 seconds until the frost protector is fully depres‐
surized.
2.
Unscrew the clamp ring 2
and remove the bowl 3 .
3.
Fill the bowl ¾ full with antifreeze.
4. Screw the bowl carefully back into place.
5. Close the shut-off valve ( B
).