EasyManuals Logo

Kamstrup MULTICAL 403 Technical Description

Kamstrup MULTICAL 403
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
MULTICAL® 403
2
Kamstrup A/S · Technical description · FILE100000166_B_EN-55121689_M1_07.2023
List of words and symbols
Word/symbol
Meaning
Unit
Expired designations
q
i
Minimum approved flow
[l/h]
Q
i
, q
vmin
, Q
min
, q
min
q
p
Permanent/nominal approved flow
[m³/h]
Q
s
, q
vmax
, Q
n
, q
n
, q
max
q
s
Maximum approved flow
1
[m³/h]
Q
max
θ
Temperature range of calculator
[°C]
θ
q
Temperature range of flow sensor (medium)
[°C]
θ
hc
Limit value for shift between heat and cooling
2
[°C]
ΔΘ
Temperature difference of inlet and outlet
[K]
t
BAT
Battery temperature
[°C]
DN
Nominal diameter
[mm]
PN
Nominal pressure
[bar]
E
c
Max. permissible error of calculator
[%]
E
f
Max. permissible error of flow sensor
[%]
E
t
Max. permissible error of temperature sensors
[%]
MPE
Maximum permissible error
[%]
PQ
Power and flow in connection with tariff
GF
Glass fibre reinforcement
KMP
Kamstrup Meter Protocol
CP
Coefficient of Performance (COP)
1
Less than an hour/day and less than 200 hours/year
2
Only available in meter type 6

Table of Contents

Other manuals for Kamstrup MULTICAL 403

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kamstrup MULTICAL 403 and is the answer not in the manual?

Kamstrup MULTICAL 403 Specifications

General IconGeneral
TypeUltrasonic Heat Meter
Flow SensorUltrasonic
Pressure RatingPN16
Battery LifeUp to 16 years
ApprovalMID Class 2
DisplayLCD
CommunicationM-Bus, Wireless M-Bus, Modbus, BACnet
Power SupplyBattery
AccuracyClass 2
Protection ClassIP54
Housing MaterialComposite
Flow Rate Range0.6 m3/h to 15 m3/h

Related product manuals