EasyManuals Logo

Kamstrup MULTICAL 403 Technical Description

Kamstrup MULTICAL 403
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
MULTICAL® 403
26
Kamstrup A/S · Technical description · FILE100000166_B_EN-55121689_M1_07.2023
Display ref.
Primary key
Display ref.
Secondary key
Heat meter
DDD = 210
Heat/cooling meter
DDD = 310
Heat meter
DDD = 410
Cooling meter
DDD = 510
Heat/cooling meter
DDD = 610
Volume meter
DDD = 710
8.0
Flow (V1)
7
8
7
7
8
6
8.1 Date for max. this year
3
7A 8A 7A 7A 8A 6A
8.2 Data for max. this year
1
8.3 Date for max yearly logger
8.4 Data for max yearly logger
1
8.5 Date for max. this month
3
7B 8B 7B 7A 8B 6B
8.6 Data for max. this month
1
8.7 Date for max. monthly logger
8.8 Data for max. monthly logger
1
8.9 Date for min. this year
3
8C
8.10 Data for min. this year
1
8.11
Date for min. yearly logger
8.12
Data for min. yearly logger
1
8.13
Date for min. this month
3
8D
8.14
Data for min. this month
1
8.15
Date for min. monthly logger
8.16
Data for min. monthly logger
1
9.0
Thermal output (V1)
8
9
8
8
9
7
9.1 Date for max. this year
3
8A 9A 8A 8A 9A 7A
9.2 Data for max. this year
1
9.3 Date for max. yearly logger
9.4 Data for max. yearly logger
1
9.5 Date for max. this month
3
8B 9B 8B 8B 9B 7B
9.6 Data for max. this month
1
9.7 Date for max monthly logger
9.8 Data for max monthly logger
1
9.9 Date for min. this year
3
9C
9.10 Data for min. this year
1
9.11 Date for min. yearly logger
9.12 Data for min. yearly logger
1
9.13 Date for min. this month
3
9D
9.14 Data for min. this month
1
9.15 Date for min. monthly logger
9.16 Data for min. monthly logger
1
10.0
Input A
4
9
10
9
9
10
8
10.1 Meter no. of Input A
9A 10A 9A 9A 10A 8A
10.2 L/imp. of input A
9B 10B 9B 9B 10B 8B
10.3 Date for yearly logger
9C 10C 9C 9C 10C 8C
10.4 Data for yearly logger
1
10.5 Date for monthly logger
9D 10D 9D 9D 10D 8D
10.6 Data for monthly logger
1

Table of Contents

Other manuals for Kamstrup MULTICAL 403

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kamstrup MULTICAL 403 and is the answer not in the manual?

Kamstrup MULTICAL 403 Specifications

General IconGeneral
TypeUltrasonic Heat Meter
Flow SensorUltrasonic
Pressure RatingPN16
Battery LifeUp to 16 years
ApprovalMID Class 2
DisplayLCD
CommunicationM-Bus, Wireless M-Bus, Modbus, BACnet
Power SupplyBattery
AccuracyClass 2
Protection ClassIP54
Housing MaterialComposite
Flow Rate Range0.6 m3/h to 15 m3/h