EasyManuals Logo

Kamstrup MULTICAL 403 Technical Description

Kamstrup MULTICAL 403
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
MULTICAL® 403
6
Kamstrup A/S · Technical description · FILE100000166_B_EN-55121689_M1_07.2023
11.2.3 HC-003-20: Wired M-Bus, inputs (In-A, In-B) ........................................................................................ 120
11.2.4 HC-003-21: Wired M-Bus, outputs (Out-C, Out-D) ................................................................................ 121
11.2.5 HC-003-22: Wired M-Bus, Thermal Disconnect .................................................................................... 121
11.2.6 HC-003-30: Wireless M-Bus, inputs (In-A, In-B) .................................................................................... 121
11.2.7 HC-003-31: Wireless M-Bus, outputs (Out-C, Out-D) ............................................................................ 122
11.2.8 HC-003-32: linkIQ/wM-Bus, inputs (In-A, In-B), EU ............................................................................... 122
11.2.9 HC-003-33: linkIQ/wM-Bus, outputs (Out-C, Out-D),EU ........................................................................ 122
11.2.10 HC-003-34: wM-Bus, inputs (In-A, In-B),912,5/915/918,5 MHz ............................................................ 123
11.2.11 HC-003-40: Analog outputs 2 x 0/4…20 mA .......................................................................................... 123
11.2.12 HC-003-42: KNX Comminication............................................................................................................ 123
11.2.13 HC-003-43: PQT Controller .................................................................................................................... 123
11.2.14 HC-003-50: Low Power Radio, inputs (In-A, In-B), 434 MHz.................................................................. 124
11.2.15 HC-003-51: Low Power Radio GDPR, inputs (In-A, In-B), 434 MHz ........................................................ 124
11.2.16 HC-003-53: LoRaWAN (Elvaco) .............................................................................................................. 124
11.2.17 HC-003-56: NB-IoT, inputs (In-A, In-B)................................................................................................... 125
11.2.18 HC-003-58: NB-IoT (Elvaco) ................................................................................................................... 125
11.2.19 HC-003-66: BACnet MS/TP, inputs (In-A, In-B) ...................................................................................... 125
11.2.20 HC-003-67: Modbus RTU, inputs (In-A, In-B) ......................................................................................... 126
11.2.21 HC-003-81: BACnet IP, inputs (In-A, In-B) .............................................................................................. 126
11.2.22 HC-003-82: Modbus/KMP TCP/IP, inputs (In-A, In-B) ............................................................................ 126
11.2.23 HC-003-83: READy Ethernet, inputs (In-A, In-B) .................................................................................... 126
11.3 Reading high resolution registers ................................................................................................................ 127
11.4 Mounting of antenna ................................................................................................................................... 127
11.5 Module retrofitting. ..................................................................................................................................... 128
11.6 Supply of modules ....................................................................................................................................... 129
12 Data communication ..................................................................................................................... 130
12.1 MULTICAL
403 Data Protocol .................................................................................................................... 130
12.2 Optical interface .......................................................................................................................................... 130
12.2.1 Power-saving in connection with the optical interface ......................................................................... 130
12.3 Data protocol ............................................................................................................................................... 130
13 Test and calibration ....................................................................................................................... 131
13.1 Meter cycle .................................................................................................................................................. 131
13.2 Test .............................................................................................................................................................. 132
13.2.1 Test of flow sensor ................................................................................................................................ 132
13.2.2 Test of calculator ................................................................................................................................... 132
13.3 High-resolution volume and energy ............................................................................................................ 133
13.4 Temperature calibration .............................................................................................................................. 133

Table of Contents

Other manuals for Kamstrup MULTICAL 403

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kamstrup MULTICAL 403 and is the answer not in the manual?

Kamstrup MULTICAL 403 Specifications

General IconGeneral
TypeUltrasonic Heat Meter
Flow SensorUltrasonic
Pressure RatingPN16
Battery LifeUp to 16 years
ApprovalMID Class 2
DisplayLCD
CommunicationM-Bus, Wireless M-Bus, Modbus, BACnet
Power SupplyBattery
AccuracyClass 2
Protection ClassIP54
Housing MaterialComposite
Flow Rate Range0.6 m3/h to 15 m3/h

Related product manuals