MULTICAL® 403
Kamstrup A/S · Technical description · FILE100000166_B_EN-55121689_M1_07.2023
7.9 Info and config logger .................................................................................................................................... 97
7.9.1 Info logger ................................................................................................................................................ 97
7.9.2 Config logger ............................................................................................................................................ 97
7.10 Summer/winter time adjustment .................................................................................................................. 98
8 Flow sensor ........................................................................................................................................ 99
8.1 Measuring principles ...................................................................................................................................... 99
8.2 Signal path and flow calculation ..................................................................................................................... 99
8.3 Flow limits .................................................................................................................................................... 101
9 Temperature sensors ........................................................................................................................ 102
9.1 Temperature sensor types ........................................................................................................................... 103
9.2 Cable effect .................................................................................................................................................. 104
9.3 Installation.................................................................................................................................................... 104
9.3.1 Identification of inlet and outlet temperature sensors .......................................................................... 104
9.3.2 Electrical connection .............................................................................................................................. 105
9.3.3 Pt500 direct short sensor set ................................................................................................................. 105
9.3.4 Pt500 ø5,0 mm / ø5,2 mm sensor types ................................................................................................ 107
9.3.5 Pt500 ø5.8 mm / ø6.0 mm pocket sensor set ........................................................................................ 109
10 Power supply ................................................................................................................................. 110
10.1 Battery, 2 x A-cells ........................................................................................................................................ 110
10.2 Lithium battery, 1 x D-cell ............................................................................................................................ 111
10.3 Lithium battery, 1 x C-cell IoT ....................................................................................................................... 111
10.4 Battery lifetimes ........................................................................................................................................... 112
10.5 230 VAC supply module ............................................................................................................................... 113
10.6 24 VAC supply module ................................................................................................................................. 113
10.7 230 VAC high-power SMPS........................................................................................................................... 114
10.8 24 VAC/VDC high-power SMPS .................................................................................................................... 114
10.9 Power consumption of mains connected meter .......................................................................................... 114
10.10 Safety transformer 230/24 VAC ................................................................................................................... 115
10.11 Supply cables for supply module .................................................................................................................. 115
10.12 Retrofitting and exchange of supply modules .............................................................................................. 116
10.13 Data-backup in case of interruption of supply ............................................................................................. 117
11 Communication modules ............................................................................................................... 118
11.1 Marking on communication modules .......................................................................................................... 119
11.2 Modules ....................................................................................................................................................... 120
11.2.1 HC-003-10: Data Pulse, inputs (In-A, In-B) ............................................................................................. 120
11.2.2 HC-003-11: Data Pulse, outputs (Out-C, Out-D)..................................................................................... 120

Table of Contents

Other manuals for Kamstrup MULTICAL 403

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kamstrup MULTICAL 403 and is the answer not in the manual?

Kamstrup MULTICAL 403 Specifications

General IconGeneral
TypeUltrasonic Heat Meter
Flow SensorUltrasonic
Pressure RatingPN16
Battery LifeUp to 16 years
ApprovalMID Class 2
DisplayLCD
CommunicationM-Bus, Wireless M-Bus, Modbus, BACnet
Power SupplyBattery
AccuracyClass 2
Protection ClassIP54
Housing MaterialComposite
Flow Rate Range0.6 m3/h to 15 m3/h