MULTICAL® 403
86
Kamstrup A/S · Technical description · FILE100000166_B_EN-55121689_M1_07.2023
CP display readings
The table below shows the CP readings in ”TECH loop”.
CP
(moving
average)
2-016-00
Current power of input
B
2-016-01
Averaging period of CP
2-016-02
Yearly date
2-016-03
Yearly data
2-016-04
Monthly date
2-016-05
Monthly data
2-016-06
Reset of CP
Situation
Handling
Different units and/or resolutions of E1 and input B
Correction for the difference in CP calculation
Reconfiguration of unit and/or resolution of E1
(B or CCC-code)
Reset of CP calculations
1
Reconfiguration of unit and/or resolution of input B
(GG-code)
Reset of CP calculations
1
Reconfiguration of presetting of input B
Reset of CP calculations
1
1
Monthly and yearly CP restart, i.e. CP is calculated over just the remaining period until the next logging. Current CP
is set at 0,0 until the daily log has logged over the configured number of days. (E.g. If the selected number of days is 5,
the meter cannot make a calculation over 5 days until the meter has carried out 6 loggings.)