Operating and appliance data
© KEB, 2012-10 COMBIVERT F5-A, -E, -H Page 7.1 - 15
7
Parameter Addr. R PG E Min. value Max. value Res. [?] Default
ru.82 Ramp val. display high-
resolution
0252h RO - - -2147483647 2147483647 1 - 0
The ramp value display high-res is displayed in ru.82.
Parameter Addr. R PG E Min. value Max. value Res. [?] Default
ru.83 Act. val. display high-
res.
0253h RO - - -2147483647 2147483647 1 - 0
The actual value is displayed in high-resolution with ru.83.
Parameter Addr. R PG E Min. value Max. value Res. [?] Default
ru.84 accessible rel. position 0254h RO - - -2147483647 2147483647 1 Inc 0
The accessible relative position is displayed with ru.84.
Parameter Addr. R PG E Min. value Max. value Res. [?] Default
ru.85 Peak encoder 1 speed 0255h RO - - 0 4095.875 0.125 rpm 0
The actual speed of encoder 1 is displayed with ru.85
Parameter Addr. R PG E Min. value Max. value Res. [?] Default
ru.86 Peak encoder 2 speed 0256h RO - - 0 4095.875 0.125 rpm 0
The peak value of encoder 2 is displayed in ru.86
Parameter Addr. R PG E Min. value Max. value Res. [?] Default
ru.87 Magnetizing current 0257h RO - - -3276.7 3276.7 0.1 A 0
The magnetizing current is displayed in ru.87.
Parameter Addr. R PG E Min. value Max. value Res. [?] Default
ru.89 actual source speed 0259h RO - - -4000 4000 0.125 rpm 0
The frequency of the actual value source is displayed in ru.89.
Parameter Addr. R PG E Min. value Max. value Res. [?] Default
ru.90 Max. torque in percent 025Ah RO - - 0.00 400.00 0.01 % 0
The maximum torque in percent is displayed in ru.90.