Karl Fischer Moisture Titrator
(for coulometric method)
MKC-710
Operation Manual
Please read this manual thoroughly in advance for the best performance of the equipment.
Overseas Division: Yamawaki Bldg 9F 4-8-21 Kudan Minami,
Chiyoda-ku, Tokyo 102-0074 JAPAN
FAX: +81-3-3237-0537, Phone: +81-3-3239-7333
E-mail: overseas-tokyo@kyoto-kem.com
URL:http://www.kyoto-kem.com
Factory: 56-2 Ninodan-cho,Shinden Kisshoin,Minami-ku,KYOTO
601-8317,JAPAN
FAX: +81-75-691-9961, Phone: +81-75-691-4122
AN 59-00392-01 Ver.00

Table of Contents

Questions and Answers

  • S
    Stacey NguyenAug 6, 2025
    What to do if KEM MKC-710 show 'Meas. Over!'?
    • A
      Amanda JonesAug 6, 2025
      If your KEM Measuring Instruments display 'Meas. Over!', it means the measurement exceeds the instrument's range. Try changing the catholyte, and if necessary, also change the anolyte. If a single measurement exceeds 300mgH2O, reduce the sample size to not exceed this limit and try again.
  • S
    shawmichealAug 12, 2025
    What to do if KEM MKC-710 Measuring Instruments show 'Over Titr!'?
    • C
      Christopher CrawfordAug 12, 2025
      If your KEM Measuring Instruments display 'Over Titr!', it indicates over-titration. This can occur if the reagent in the cell has too much iodine, or if the titration cell is under direct sunlight, or if the anode is stained. Add water to the cell. Refrain from direct sun’s rays or use a brown cell. Clean the inner burette and the electrode.
  • S
    Shannon ClarkAug 18, 2025
    What to do if KEM MKC-710 Measuring Instruments show 'Electrode short!'?
    • P
      Pamela QuinnAug 18, 2025
      If your KEM Measuring Instruments display 'Electrode short!', it could be due to several reasons. It may be because the twin Pt pins of the electrode are in contact, it is over-titration, or the tip of the electrode is cracked. Correct the two pins to extend in parallel. Add water to polarize the cell. Replace the detection electrode.
  • E
    erinoliverAug 25, 2025
    How to fix 'Electrode Open!' error on KEM Measuring Instruments?
    • T
      Tyler SmithAug 25, 2025
      If your KEM Measuring Instruments display an 'Electrode Open!' error, it could be due to a disconnected connecting cable or a broken/loosely connected electrode cable. Check the connection between the detection electrode and stirrer. If the cable is broken, replace the electrode.
  • A
    Amber CookAug 30, 2025
    What to do if KEM MKC-710 Measuring Instruments show 'Current Error!'?
    • J
      Jason WashingtonAug 30, 2025
      If your KEM Measuring Instruments display 'Current Error!', it suggests that the sample liquid resistance is too high, or the electrode cable is broken, preventing current flow for electrolysis in the inner cell. Check the electrode connection and reduce the sample size.

Summary

Introduction

Features

Lists key features of the MKC-710 moisture titrator, covering design, operation, and functionality.

Important Information

Safety and Installation Guidelines

Covers symbol meanings, installation precautions, and power source safety.

About the Manual

Manual Navigation Symbols

Explains the meaning and purpose of 'Note' and 'Hint' symbols used in the manual.

Preparations for Measurement

Supplied Parts

Lists all parts included with the MKC-710 unit for initial setup.

Installation and Start-up Procedures

Covers assembly of the titration cell, clamp filter, and power cable connections.

Solvent Change Unit Installation

Guides on installing manual and automatic solvent change units.

Parts Configuration and Functions

Component Identification and Key Functions

Identifies components, explains key functions, and describes display messages and basic operations.

System Settings

Guides on changing display language and setting the instrument's date and time.

Basic Operation

Measurement Workflow

Outlines measurement steps, cell assembly, and reagent filling procedures.

Sample Measurement and Data Handling

Details sample measurement, data recalculation, batch processing, and USB data storage.

Method Condition Management

Explains saving and loading method conditions to/from a USB drive or PC.

Method Setup

Method Configuration and Locking

Introduces method setup, configuration, and procedures for locking/unlocking methods.

Titration and Calculation Parameters

Guides on setting titration modes, cell types, and calculation parameters.

Calculation Formulas and Reports

Provides calculation formulas and explains how to configure report settings.

Function Tools

Instrument Features Overview

Introduces features like manual operation, data file management, history, sample, and reagent settings.

Specialized Measurements

Covers bromine number/index measurement principles, preparation, and procedure.

Connectivity and Peripherals

Details balance setting, USB device connection, and Android device integration for measurements.

System Setup

Interface and Communication Settings

Configures RS-232C, data acquisition software, printer, balance, and USB connections.

User and System Configuration

Covers operator management, date/time, language, beep, parameter clearing, and serial number display.

Display and Other Settings

Configures LCD contrast, print headers/footers, and automatic mean value settings.

Maintenance

Daily Maintenance Procedures

Essential instructions for daily upkeep, including greasing, septum/desiccant replacement, and checks.

Other Maintenance Tasks

Covers instrument storage, electrode/cell cleaning, pump tube/filter replacement, and battery replacement.

Troubleshooting

Error and Alarm Message Resolution

Lists common error and alarm messages with their causes and remedies.

Diagnostic Flowcharts

Provides flowcharts for diagnosing issues like stirrer malfunction, high drift, over-titration, and repeatability.

Specific Problem Resolution

Addresses specific issues like jammed glass contacts and clogged drain pumps.

Others

Parts, Options, Specifications, and Standards

Lists parts, optional peripherals, technical specifications, and international standards.

Measurement Principles and Reagents

Explains measurement principles and recommends Karl Fischer reagents by sample type.

Parameter Lists

Details setup and method parameters, including their default values and selection ranges.

Warranty and After-sales Service

Warranty Terms and Exclusions

Outlines the product warranty period, terms, exclusions, and disclaimer of liability.

KEM MKC-710 Specifications

General IconGeneral
BrandKEM
ModelMKC-710
CategoryMeasuring Instruments
LanguageEnglish