EasyManua.ls Logo

Keysight Technologies MSO-X 2002A User Manual

Keysight Technologies MSO-X 2002A
352 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #108 background imageLoading...
Page #108 background image
108 Keysight InfiniiVision 2000 X-Series Oscilloscopes User's Guide
7 Serial Decode
With the DSOX2EMBD license, you can decode I2C (Inter-IC) and SPI (Serial
Peripheral Interface) serial buses. See:
“I2C Serial Decode" on page 322.
“SPI Serial Decode" on page 331.
With the DSOX2COMP license, you can decode many UART (Universal
Asynchronous Receiver/Transmitter) protocols including RS232
(Recommended Standard 232). See “UART/RS232 Serial Decode" on
page 339.
To determine whether these licenses are installed on your oscilloscope, see “To
display oscilloscope information" on page 261.
To order serial decode licenses, go to www.keysight.com and search for the
product number (for example, DSOX2AUTO) or contact your local Keysight
Technologies representative (see www.keysight.com/find/contactus).
Lister
Lister is a powerful tool for investigating protocol failures. You can use Lister to
view large amounts of packet level serial data in a tabular format, including time
tags and specific decoded values. After pressing the [Single] key, you can press the
Scroll Lister softkey and then rotate the Entry knob to select an event and press the
Zoom to Selection softkey to jump to the event.
To use the Lister:
1 Set up trigger and decode on the serial data signals to be analyzed.
2 Press [Serial] > Lister.
3 Press Display; then, turn the Entry knob to select the serial slot (Serial 1) on
which the serial bus signals are being decoded.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies MSO-X 2002A and is the answer not in the manual?

Keysight Technologies MSO-X 2002A Specifications

General IconGeneral
Form FactorBenchtop
Vertical Resolution8 bits
Display Size8.5 inches
Waveform Update Rate50, 000 waveforms/sec
Sample Rate2 GSa/s
Memory Depth1 Mpts
Display8.5 inch
Display TypeWVGA LCD
Waveform Capture Rate50, 000 waveforms per second
Input Impedance1 MΩ
Trigger TypesEdge, Pulse Width, Pattern, Serial
Operating Temperature0°C to +50°C
Weight5.5 kg

Summary

1 Getting Started

Connect Probes to the Oscilloscope

Guides on connecting probes to the oscilloscope channel BNC connectors.

2 Horizontal Controls

To adjust the horizontal (time/div) scale

Adjusts the time per division setting using the horizontal scale knob.

To adjust the horizontal delay (position)

Controls horizontal positioning of the trigger point relative to the time reference.

3 Vertical Controls

To adjust the vertical scale

Sets the vertical sensitivity (volts/division) for each analog channel.

To adjust the vertical position

Moves the waveform up or down on the display for better viewing.

4 Math Waveforms

To perform a transform function on an arithmetic operation

Performs operations like add, subtract, multiply, and FFT on analog signals.

6 Digital Channels

To connect the digital probes to the device under test

Guides on connecting digital probes for mixed-signal oscilloscope use.

7 Serial Decode

10 Triggers

Adjusting the Trigger Level

Sets the vertical level for analog channel edge detection.

Pattern Trigger

Triggers based on a specific logic pattern across multiple channels.

11 Trigger Mode/Coupling

12 Acquisition Control

Running, Stopping, and Making Single Acquisitions (Run Control)

Manages the oscilloscope's acquisition process using Run/Stop and Single keys.

Selecting the Acquisition Mode

Chooses acquisition modes like Normal, Peak Detect, Averaging, High Resolution.

13 Cursors

To make cursor measurements

Uses horizontal and vertical markers for custom measurements.

14 Measurements

To make automatic measurements

Configures and displays automatic measurements on waveforms.

15 Mask Testing

To create a mask from a "golden" waveform (Automask)

Automatically generates a mask from a reference waveform.

17 Waveform Generator

18 Save/Recall (Setups, Screens, Data)

21 Web Interface

23 CAN/LIN Triggering and Serial Decode

Setup for CAN Signals

Connects to CAN signals and specifies parameters for capture.

CAN Triggering

Configures triggers for CAN messages based on frame ID, data, or errors.

CAN Serial Decode

Decodes captured CAN data and displays it in a readable format.

24 I2C/SPI Triggering and Serial Decode

Setup for I2C Signals

Connects to I2C signals and sets threshold voltage levels.

25 UART/RS232 Triggering and Serial Decode

Related product manuals