EasyManuals Logo

Keysight E36200 Series User Manual

Keysight E36200 Series
249 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
Resetting the LAN
Press Utilities > I/O Config > LAN Settings > Set to Default resets the LAN settings to their factory default values.
All default LAN settings are listed under Non-volatile Settings in Programming Guide.
Press Utilities > I/O Config > LAN Status > LAN Reset resets the LAN using its current settings and enables DHCP
and DNS. The LAN Reset softkey also clears any user-defined Web Interface password.
Modifying the LAN settings
As shipped from the factory, the instrument pre-configured settings should work in most LAN environments. Refer
to Non-Volatile Settings in the Programming Guide for information on the factory-shipped LAN settings.
Press Utilities> I/O Config > LAN Settings to access the LAN Settings window. From this menu, you can manually
configure the LAN settings.
DHCP
DHCP (Dynamic Host Configuration Protocol) can automatically assign a dynamic IP address to a LAN device. This is
typically the easiest way to configure the instrument for LAN.
This setting is non-volatile; it will not be changed by power cycling or *RST or SYSTem:PRESet.
1. Press Utilities > I/O Config > LAN Settings > DHCP On to use DHCP to automatically assign an IP address.
2. Press Back. You will be prompted by the below message.
Keysight E36200 Series User's Guide 49

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight E36200 Series and is the answer not in the manual?

Keysight E36200 Series Specifications

General IconGeneral
BrandKeysight
ModelE36200 Series
CategoryPower Supply
LanguageEnglish

Related product manuals