Configuring the Output Turn On Turn Off Sequence (E36233A and E36234A Only)
Turn-on and turn-off delays control the turn-on and turn-off timing of the outputs in relation to each other.
Step 1 Set the output voltage and current of the output channels:
Refer to steps 1 and 2 under Controlling the Outputs and set the output voltage and current values of all outputs
that will be sequenced.
Step 2 Configure the turn-on turn-off delays:
Press Output Settings to access the Output Settings On/Off Delays. Enter the On Delays and Off Delays for all
outputs that will participate in the output on/off delay sequence. Values can range from 0 to 3600 seconds.