8 Appendix A: Supported EtherNet/IP Objects and Attrib-
utes
8.1 Position Controller Object 0x25
Attribute
ID
(Decimal
Value)
Name Access
Rule
Type Description
1 Number of
Attributes
Get USINT Returns the total number of attributes supported by this
object in this device.
2 Attribute List Get Array
of
USINT
Returns an array with a list of the attributes supported by
this object in this device.
3 Mode Get/Set USINT Operating mode. 0 = Position mode(default), 1 = Velocity
mode, 2 = Torque mode.
4 Position
Units
Get/Set DINT Position Units ratio value is the number of actual position
feedback counts equal to one position unit (default 1).
5 Profile Units Get/Set DINT Profile Units ratio value is the number of actual position
feedback counts per second or second2 equal to one velo-
city, acceleration or deceleration unit (default 1).
6 Target Pos-
ition
Get/Set DINT Specifies the target position in counts.
7 Target Velo-
city
Get/Set DINT Specifies the Target Velocity in counts per second.
8 Acceleration Get/Set DINT Not used yet.
9 Deceleration Get/Set DINT Not used yet.
10 Incremental
Position
Flag
Get/Set BOOL Incremental Position Flag 0 := absolute, 1:= incremental.
11 Load
Data/Profile
Handshake
Get/Set BOOL Used to Load Command Data, Start a Profile Move, and
indicate that a Profile Move is in progress.
17 Enable Get/Set BOOL Enable Output (same as DRV.EN).
25 Torque Get/Set DINT Output torque.
58 Load Data
Complete
Get/Set BOOL Indicates that valid data for a valid I/O command message
type has been loaded into the position controller device.
100 Home Mode Get/Set INT See home mode section of the AKD User Manual
101 Home Move Set BOOL Initiate a home move.
Ethernet IP with RSLogix | 8 Appendix A: Supported EtherNet/IP Objects and Attributes
Kollmorgen | kdn.kollmorgen.com | November 2018 73

Table of Contents

Other manuals for Kollmorgen AKD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD and is the answer not in the manual?

Kollmorgen AKD Specifications

General IconGeneral
Control ModesTorque, Velocity, Position
Communication InterfacesEtherCAT, CANopen
Feedback OptionsResolver
SafetySTO (Safe Torque Off), SS1 (Safe Stop 1)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature
Operating Temperature Range0°C to 55°C
Humidity5% to 95% non-condensing