KONE NanoSpace™
Owners Manual
185 (196) OM-01.03.086
(B) 2016-01-11
© 2014 KONE Corporation
All rights reserved.
F.7 Wire breaks
Wire break on surface
F.8 Local bend
Appearance Possible root cause Action
1. Presence of particles
between belt and p
ulley /
traction sheave.
2. Bending fatigue.
Remove the elevator from
service immediately!
Replace the belt.
1. Remove particles. Check
pulleys and tract
ion
sheave and replace if
damaged.
Appearance Possible root cause Action
1. Improper installation.
2. Bending life time reached.
3. Belt folded or twisted.
Remove the elevator from
service imme
diately!
Replace the belt.