10.10 Finalizing the maintenance
32 Repeat the check with the other belt
slack switch. See steps 27 – 30
33 Remove cable tie from the belt slack
switch. If you
used the alternative
method, then remove the screwdriver or
locking pin.
34 Go to the landing. See steps 15 – 18.
Step Action Note / Illustration / Method
1 Go to the maintenance access panel
(MAP).
2 Reset the Shaft Access Monitor (SAM),
if a
pplicab
le.
Related information: APPENDIX B.
Resetting the safety devices.
3 Reset the pit safety device. Related information: APPENDIX B.
Rese
tting the safety devices.
4 Switch off the Recall Drive Feature
(RDF).
POS 270.
5 Close and lock the maintenance access
panel.
6 Perform a test run
for the elevator.
7 Go to the Maintenance Access Panel
(MAP).
8 Switch on the Recall Drive Feature.
(RDF)
POS 270.
Step Action Illustration/Note
1072612.wmf