8.8 Ropes
Check the ropes for:
– Visible breaks
– Incorrect tension
8.8.1 Safety measures
Before starting work, note the following:
– All safety measures for normal elevator maintenance must be implemented and local
sa
fety re
gulations must be followed.
8.8.2 Checking visible breaks
Examination according to visible wire breaks - DIN 15020 sheet 2, transmission groups 2
m
+
5
m
For further surveillance the prescriptions of DIN 15020 sheet 2 3.4 have to be observed.
Rope
specificati
ons
Number of load
bearing wires in
outer layers
Number of visible wire
breaks on a length of
6 x rope dia.
Number of visible
wire breaks on a
length of
30 x rope dia.
F819 S-FE
819S + FC(PP)
819S + FC(NF)
152 10 19
F819 W-FE 152 13 26
F819 S-FE DT 152 10 19
PAWO F3 and
819S + 87 + PP
7-20 mm
6.5 mm
15
114
10
6
19
12
PAWO F7 8-20 mm 152 13 26
PAWO F10 6-12 mm
13-22 mm
117
144
10
13
19
26
PAWO 819 W 152 13 26
PAWO 836 WS 288 24 48
PAWO F 4e 152 10 19
PAWO F 5e 114 6 12
PAWO F 1 and
619S + FC (PP)
6x19
6x19S
6x19W
8x19S
114
114
114
152
10
6
10
10
19
12
19
19