EasyManua.ls Logo

Kone NanoSpace - Safety Gear Tests

Kone NanoSpace
197 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
KONE NanoSpace™
Owners Manual
100 (196) OM-01.03.086
(B) 2016-01-11
© 2014 KONE Corporation
All rights reserved.
10.8 Safety gear tests
The following sections describe the safety gear tests.
CAUTION! The safety gear must be tested with empty elevator car at inspection drive
speed.
Step Action Illustration/Note
1 Go to the Maintenance Access Panel. If the elevator has Shaft Access Monitor
(SAM), reset it accord
ing to APPENDIX
B.
2 Disable the landing calls.
LCEUI switch 261.
3
Disable the door opening.
LCEUI switch 263.
2 Make a car call to two floors above the
bottom floor from the
Maintenance
Access Panel (MAP).
3 Switch on the Recall Drive Feature
(RDF).
POS 270.
4 Drive on RDF so that the elevator car
roof level
is in the middle of the landing
door.
5 Close and lock the MAP.
6 Go to the floor where the elevator is
located and check the
elevator car
position.
1. Open the landing door slightly with
emergency opening key. (Max. 100
mm.)
2. Check the elevator car position.
3. Close the landing doors.
4. Check that the landing door is
mechan
ically locked.
1085428.wmf

Table of Contents